This basic device for qualitative and quantitative analysis is an essential laboratory analytical instrument widely applied in experiments of clinical trials, metallurgical industry, geological environmental protection, chemical machinery manufacturing production, etc., also for instruction and research.
A. CT-5,6 Series are advanced single beam design consisting of 5 models. Different one with different bandwidth and wavelength accuracy. All of them provide excellent performance for measurement in the range of 190nm to 1100nm.
B. CT-5,6 series:-
- All software methods are included as built-in standard, thus eliminating the need for software options.
- Online software upgrade via Internet helps to keep your software up-to-date.
- Data Download-to-PC software expands the data storage to unlimited.
C. The CT-5,6 series are suitable for clinical lab applications, pharmaceutical and biochemical as well as routine applications such as quantitative analyses, kinetics, wavelength scanning, multiple components and DNA/Protein analysis.
D. PC Windows® application software and built-in software make this instrument versatile.
FEATURES
A. CT-5, CT-6 series with large graphic LCD display (320 × 240) to directly show graphs on the screen.
B. Unique pre-aligned deuterium lamp for easy lamp replacement to avoid optical adjustment.
C. GLP self-calibrated function can automatically check wavelength and photometric accuracy using validation report.
D. Powerful integrated software for data acquisition:-
- Quantitative: Establish or use stored calibration equation to measure the concentration of unknowns.
- Kinetics: Measurement of absorbance changing vs. time with reaction rate calculation function.
- Wavelength Scanning: Spectrum scan of sample at any selected wavelength range with choice of scanning speed and wavelength interval.
- Multi-Wavelength: Measurement at multiple wavelengths to analyze and determine the composition of mixtures.
- DNA/Protein: Calculation of concentration and DNA purity. Ratio at other wavelengths can be measured.
E. Other features include:-
- System examination: Automatic wavelength check, automatic light filter detection, automatic energy detection, and other automatic functions.
- Photometric switch: Able to switch light source in the specific range.
- Photometric cutoff: Automatic cutoff of deuterium lamp and halogen lamp to extend their durability.
- Power failure protection: Research data can be saved and restored when there is power failure.
- Software: Application software can be connected to computer to control equipment operation and to analyze experimental data.
Packing List
- Spectrophotometer......................................................1
- 4 cell holder for 10mm Squ. Cuvette............................1
- Mains Lead................................................................... 1
- Cuvettes...................................................................Set of 4, glass & Set of 2, quartz.
- USB Cord......................................................................1
- User Manual.................................................................1
- UV-Vis Analyst Software...............................................1
- Software Manual..........................................................1
Optional Accessories
- Single cell holder for 10mm
- Cylindrical cell holder.
- Test tube holder (ø8-ø22mm).
- Long path cell holder.
- 4-Cell holder for up to 50mm squ. Cuvette.
- 4-Cell holder for up to 1000mm squ. Cuvette.
- Micro cell holder.
- Water-jacketed cell holder.
- Peltier/sipper system
- 8-position auto cell changer.
- Reflectance meachment attachment printer.
|